| Product Center |
|
 |
|
| Products In Different Industries |
|
|
|
| 400Hz System |
|
|
inverter output transformer by stray inductance output filter inductance
|
Used for medium and high-frequency online UPS circuit, the inverter is in SPWM mode, e.g. turning the stable DC voltage which is by co-mmercial power rectified and storage ... |
GO! |
outlet transformation by stray inductance filtering
|
90kVA 400Hz outlet transformation, filter with specially designed stray inductance and the output filter inductance is no need
... |
GO! |
phrase –shifting reactor
|
30kVA Phrase –shifting reactor .Phrase –shifting reactor is used in controlled and uncontrolled rectifying circuit, which can largely reduce the
... |
GO! |
50Hz input reactor
|
115A,0.4mH,50Hz three-phrase reactor: dielectric strength AC 2500V/1min, dielectric class: F, insulation resistance≥100MΩ/500V |
GO! |
400Hz output filter inductor
|
80A,240μH,400Hz output filter inductor: dielectric strength AC 2500V/1min, dielectric class: F, insulation resistance≥100MΩ/500V |
GO! |
400Hz system-duty transformer
|
The 400Hz medium frequency transformer and its supported reactor have been in mass production. Aircraft power installed with our transformer ...
|
GO! |
| 500Hz System |
|
|
| 500Hz system-duty transformer |
0.5kVA-30kVA/500Hz system-duty transformer |
GO! |
| |
|
 |
|
|
| Railway & Urban Light Rail |
|
| Subway/Light Rail Secondary Power System-duty transformer & inductor |
90kVA secondary power system
|
Inverter output transformer that removes the output harmonics by connecting two transformers by Dy and Dz connection serially.
60kVA/ input 370V/ output 110V
... |
GO! |
80kVA secondary power system
|
Inverter output transformer with auxiliary iron core, the spurious inductance of the transformer is used as a filter inductor. 65KVA,input 650V output
... |
GO! |
45kVA secondary power system
|
Inverter output transformer by stray inductance output filter inductance 31KVA, input 1100V output 122V, 1KHz: good water resistance, primary ... |
GO! |
| Railbound rehical-duty transformer and reactor (choke) |
6kVA/540V input 110V output /16kHz transformer
|
6kVA/540V input 110V output /16kHz transformer
dielectric strength: AC 3000V/1min, dielectric class: F, insulation resistance≥100MΩ/500V
...
|
GO! |
| 60A/250μH output filter inductor |
60A/250μH output filter inductor dielectric strength: AC 2500V/1min, no flashover, fire striking and discharge ... |
GO! |
500A/0.4mH/50Hz four-phrase boost restricting rectifying inductor
|
dielectric strength: AC 2500V/1min, dielectric class: H, insulation resistance≥100MΩ/500V, temperature rise less than 100K
...
|
GO! |
Diesel locomotive air conditioner electric-duty transformer and reactor
|
60A/4mH DC reactor |
GO! |
| Carriage Secondary Power System-duty Transformer & Inductor |
| 35A/250μH filter inductor |
dielectric strength: AC 2500V/1min, no flashover, fire striking and discharge, dielectric class: F, insulation resistance≥100MΩ/500V |
GO! |
9KW, output 100V/80A,20kHz
|
dielectric strength: AC 2500V/1min, no flashover, fire striking and discharge, dielectric class: F, insulation resistance≥100MΩ/500V
|
GO! |
| |
|
 |
|
|
|
|
converter input reactor
|
Installed in the input end of the converter for restraining its harmonic from transferring to electric network and reducing the interference to other ... |
GO! |
output reactor 0~100Hz
|
Installed in the output end of the converter for restraining the capacitive charge current of the cable that connects the converter and the ... |
GO! |
output reactor
0~400Hz
|
Installed in the output end of the converter for restraining the capacitive charge current of the cable that connects the converter and the ...
|
GO! |
converter DC reactor
|
Installed behind the rectifying circuit for restraining its ac ripple stacking one the D.C , promoting the converter power factor and restraining the ... |
GO! |
| converter output du/dt suppression inductor |
Adaptive to 75kw converter output du/dt suppression inductor ... |
GO! |
| |
|
 |
|
|
|
| Common Switching Power Supply Transformer & Reactor |
Charge power supply-duty inductor
|
Charge power supply-duty inductor
... |
GO! |
high-power UPS output reactor
|
50KVA,110V input 220v output, 50Hz: dielectric strength: AC 3500V/1min, dielectric class: H, insulation resistance≥100MΩ/500V, leakage
... |
GO! |
high-power UPS output transformer
|
50KVA,110V input 220v output, 50Hz: dielectric strength: AC 3500V/1min, dielectric class: H, insulation resistance≥100MΩ/500V, leakage ... |
GO! |
30kVA three-phrase output transformer by inductance output filter inductance
|
dielectric strength: AC 2500V/1min, dielectric class: F, insulation resistance≥100MΩ/500V, leakage inductance <0.2mH temperature rise <80K |
GO! |
| Power system-duty Bi-isolation input, output transformer system |
Input transformer: 3kvA, input 220v output 220v: dielectric strength: AC 2500V/1min, insulation resistance≥100MΩ/500V, dielectric class: F, leakage inductance <1mH temperature rise <100K
|
GO! |
Charge power supply-duty transformer
|
9.5KW,20kHz,30A output: leakage inductance <10mH dielectric strength: AC 3750V/1min, insulation resistance≥100MΩ/500V,dielectric class..
|
GO! |
| Electric motor car heavy current switching regulator charger-duty transformer |
110V/100A transformer for output charger use: dielectric strength: AC 3750V/1min, insulation resistance≥100MΩ/500V, dielectric class: F, temperature rise <100K
|
GO! |
common UPS reactor
|
50Hz,3kVA input 220v output 220v: dielectric strength: AC 2500V/1min, dielectric class: F, insul-ation resistance≥100MΩ/500V, leakage ...
|
GO! |
| common UPS transformer |
50Hz,3kVA input 220v output 220v: dielectric strength: AC 2500V/1min, dielectric class: F, insulation resistance≥100MΩ/500V, leakage ...
|
GO! |
| Other Switching Power Supply Transformer & Reactor |
high frequency filter inductor
|
5A/1.85mH:dielectric strength: 2500V/1min,insulation resistance≥100MΩ/500V,dielectric class: F
|
GO! |
| PFC inductor |
5.5A/10mH:dielectric strength: 2500V/1min,insulation resistance≥100MΩ/500V,dielectric class: F
|
GO! |
| AC/DC.DC/DC.DC/AC power supply high-frequency transformer |
2.4kW,20kHz:leakage inductance <10mH, dielectric strength: 2500V/1min,insulation resistance≥100MΩ/500V,dielectric class: F
...
|
GO! |
| |
|
 |
|
|
| Marine & Offshore Petroleum Platform |
|
|
Helicopter platform-duty AC/DC systematic transformer
|
Transformer pulse frequency 27kHz thermal endurance class:H ,leakage inductance <5μH, good radiating, convenient maintenance ... |
GO! |
three-phrase UPS auxiliary iron core output transformer
|
Electric strength: AV 2500V/1min, insulation resistance ≥100MΩ/500V, dielectric class: H ... |
GO! |
monophrase trans-former UPS auxiliary iron core output transformer
|
dry self-cooled, dielectric and thermal endurance class: H, primary leakage inductance: 0.2mH-0.4 mH, reliable performance, good consistency ...
|
GO! |
| |
|
 |
|
|
|
|
voltage stabilizing transformer
|
Voltage stabilizing transformer is a magnetic saturation ferromagnetic resonance type AC voltage regulator. It is used in the equipment ... |
GO! |
pulse transformer
|
Output 22-24 pulse inductor, constantly flow 30 A DC current. Pulse transformer is a special kind of electronic transformer, what it inverters is ... |
GO! |
air-cored inductor
|
Air-cored reactor has no iron core and only has winding, the magnetic circuit is non-conducing magnet so the magnetic resistance is big ...
|
GO! |
| induction heating transformer |
1000kVA |
GO! |
| converter output set up transformer |
1KW,input 140V, output 151V (two sets), operating frequency : 50Hz-400Hz, dielectric strength: AC 2000V/1min, no flashover, fire striking and ... |
GO! |
| |
|
 |
|
| |
|
|
|
|
|
|
|
|
|